PV input mode
By default, the PV input mode is set to independent (1).
Note: If, for example, parallel input is set to independent,
this will result in unbalanced PV output.
To set a different PV input mode, use the up/down keys   /  
to select the desired one from the following modes:
1: Independent (Default setting for customers)
2: Parallel
3: Constant voltage
Use the enter key
or the escape key
to the system setting options.
Zero export / anti-reflux
When this option is enabled, the grid feed-in of the inverter
is prevented.
When disabled, the mains feed-in power limit can be set.
By default, it is disabled.
To change the current setting, select the desired
of the two options with the up/down keys   /   :
1: Zero export enabling / disabling
2: Setting the max. grid feed-in power
Use the enter key
or the escape key
to the system setting options.
Setting the grid feed-in power
Set the max. grid feed-in power by adjusting the individual
digits of the input value with the up/down keys  / 
after selecting the corresponding option (POWER)
and confirm with the enter key .
(Setting "0000" corresponds to zero export).
To cancel the process and return to the previous menu,
press the escape key .
to confirm your selection
to cancel the process and return
to confirm your selection
to cancel the process and return
Operation and Setting
−−INPUT MODE−−
1. INDEPENDANT
2: PARALLEL
3: CV
−−ZERO EXPORT−−
1: ENABLE
2: POWER
−WAKE-UP TIME−
INPUT: 060 min