Herunterladen Diese Seite drucken

KKT KOLBE HKW10NVP3 Benutzerhandbuch Seite 206

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation and Setting
Battery Wake-up (BAT WAKE-UP)
If the battery is very weakly charged,
it is automatically switched off by the BMS for protection
and must be restarted manually.
If battery wake-up is enabled, the inverter sends a signal
via the BMS, if applicable at the set time intervals,
by which the battery will automatically be restarted
and its charge level and depth of discharge is checked.
To disable/enable the function and/or adjust the time set-
ting for this if applicable, first select the corresponding one
of the two options with the up/down keys
1: Battery wake-up enabling
2: Time interval setting
Confirm the selection with the enter key
to access the corresponding settings menu:
Dis-/Enabling of the function (WAKE-UP ENB)
Enable or disable the battery wake-up by selecting the de-
sired one of the two options with the up/down keys
1: Battery wake-up disabling
2: Battery wake-up enabling
Confirm the selection with the enter key .
Time setting of the function (WAKE-UP Time)
Set the time interval for waking up the battery regularly
by adjusting the individual digits of the input value with the
up/down keys  /  after selecting the time setting (TIME)
and confirm with the enter key .
To cancel the process and return to the respective
previous menu, press the escape key .
70
 /  :
 /  :
−BAT WAKE-UP−
1: ENABLE
2: TIME
−WAKE-UP TIME−
INPUT: 060 min

Werbung

loading

Diese Anleitung auch für:

Kktnvb5.1