Operating Principle and Use of the System
Work mode BAT PRIORITY (Battery priority)
The battery will get charged with the power generated
by the PV system or from the grid.
The stored energy is not consumed when grid power is available,
but is used exclusively to supply the loads connected to BACKUP
in the event of a grid failure / disconnection, if the energy generated
from the PV modules is not sufficient for this.
PV
Public grid
Backup loads
Battery
storage
Work mode PEAK SHIFT
The battery is charged or discharged with the set power
(SETUP / BAT SETTING / CHG POWER) the corresponding set
times (SETUP / SYS SETTING / WORK MODE / PEAK SHIFT /
TIMESETTING).
Particularly in areas with large differences in energy prices,
costs can be reduced by avoiding the use of electricity from
the public grid at peak load times.
Energy price
Zeit
Charging
Discharging
the battery
the battery