Operation and Setting
Setting for using of an ammeter instead of
current transducers (CT OR METER)
The inverter of your energy storage system supports
the connection of a three-phase ammeter instead
of the supplied current transducers in order to record
the mains voltage.
Make sure that of the following two options, the one is set
that corresponds to the equipment you are using:
1: Use of the supplied current transducers (CT)
2: Use of a three-phase ammeter
To change the current setting, use the up/down keys   /  
to select the corresponding option and confirm it with the
enter key .
To cancel the process and return to the system setting
options instead, use the escape key .
AC couple enabling
When connecting another inverter by AC side for charging
the battery storage, the AC couple must be enabled.
Notes:
Charging the battery storage with an on-grid inverter
is not possible with this function.
The HKW5000P1 hybrid inverter will still be required.
When connecting an additional inverter, pay attention
to the corresponding cable dimensioning.
For the corresponding system configuration, see the connec-
tion diagram in the section "Operating Principle and Use ...".
Use the up/down keys   /   to select the corresponding one
of the two options:
1: AC couple disabling
2: AC couple enabling
Use the enter key
or the escape key
to the system setting options.
66
to confirm your selection
to cancel the process and return
−CT OR METER−
1. CT
2. METER
−AC COUPLE−
1. DISABLE
2. ENABLE