Discharge depth (DOD ENABLE > DISCHDEPTH)
When the SOC of the battery is less than the set discharge
depth, the battery will no longer discharge and an error mes-
sage for low capacity of the battery is given (W13).
Set the discharge depth in the battery parameter setting.
Note: This option should always be activated.
If deactivated, the battery storage is discharged to 0 %.
Use the up/down keys   /   to select the desired one
of the two options:
1: Disabling the discharge limits
2: Enabling the discharge limits
Use the enter key
or the escape key
to the system setting options.
Generatorenabling(GENERATOR)
Activate this option if you want to use a secondary power
generation system (e.g. wind / diesel generator)
in connection with the energy storage system.
In the mode of enabling generator, the frequency protection
range measured by AC will be relaxed to + -10%,
the frequency protection range at 50Hz is 45Hz-55Hz,
and that of 60Hz is 54Hz-66Hz.
For generators that must be connected for AC measurement,
the function must be disabled.
Use the up/down keys   /   to select the desired one
of the two options:
1: Generator disabling
2: Generator enabling
Use the enter key
or the escape key
to the system setting options.
to confirm your selection
to cancel the process and return
to confirm your selection
to cancel the process and return
Operation and Setting
−DISCHDEPTH−
1. DISABLE
2. ENABLE
−GENERATOR−
1. DISABLE
2. ENABLE
65