 Notesonvoltageclassification(DVC):
The DVC ((Decisive Voltage Classification) indicates the
minimum required level of protection for the circuit.
DVC
A *
B
C
The table values in parentheses are to be used for PCE
connectors rated for installation in wet locations
in compliance with the ambient conditions, in particular
the humidity limits (see relevant sections under "Mount-
ing the system" or "Storage instructions" / "Technical
data").
* DVC-A circuits are allowed under fault conditions to
have voltages up to the DVCB limits, for maximum 0.2 s.
36
Limits of working voltage
a.c. voltage
a.c. voltage
r.m.s.
U
ACL
≤25
(16)
50
(33)
>50
(>33)
d.c. voltage
peak
U
ACPL
≤35.4
(22.6)
71
(46.7)
>71
(>46.7)
mean
U
DCL
≤60
(35)
120
(70)
>120
(>70)