Operation and Setting
Setting the battery discharge/charge time(s)
after selecting PEAK SHIFT mode
When selecting the PEAK SHIFT mode, set the charging and
discharging time as follows:
It is possible to set two charging and discharging times.
For this purpose, make sure that the time setting of the
inverter corresponds to the local time.
Use the up/down keys  /  to select the time setting
from the following options:
1: Charge / discharge time setting
2: Battery charge from the grid
3: Battery discharge to the connected load
To confirm your selection and enter the time setting menu,
use the enter key .
Set the charging and discharging time
by using the up/down keys  /  to select the desired one
of the following options:
Start of charging time 1/2 (CHA STAR1/2)
End of charging time 1/2 (CHARG END1/2)
Start of discharging time 1/2 (DIS START1/2)
End of discharging time 1/2 (DISC END1/2)
Use the enter key
value with the up/down keys  /  and confirm each input
by pressing the enter key .
To return to the work mode setting, use the escape key .
 Note:
When commissioning the system or starting operation after
a long period of non-use, first select the battery priority mode
(BAT PRIORITY).
This is necessary to calibrate the SOC (battery charge level).
Otherwise, the battery will not be charged and a fault message
will appear.
60
to confirm the selection, set the time
−PEAK SHIFT−
1: TIMESETTING
2: CHARGE
3: DISCHG
CHA STAR 1:
00:00
CHAR END 1:
00:00
DIS
STAR 1:
00:00
DISC
END 1:
00:00
CHA STAR 2:
00:00
CHAR END 2:
00:00
DIS
STAR 2:
00:00
DISC
END 2:
00:00