PIKO S / PIKO L / PIKO M / CUBO S / CUBO L / CUBO M
In general, a distance to the wall of at least 50 mm must be main-
tained. For safety reasons and for the purposes of fire protection,
larger clearance distances must be ensured for walls needing pro-
tection or for combustible construction materials.
A minimum distance of 100 mm (Fig. 8a, 8c) is to be maintained
between construction materials, furniture, decoration or curtains to
the rear of the stove. If the stove is rotatable, a minimum distance
of 311 mm (Fig. 8b) is to be maintained to guarantee sufficient
thermal protection! If wall coverings made out of combustible mate-
rials and without thermal radiation protection have been fitted, the
clearance distance to the rear is to be increased from 345 mm to
740 mm. No combustible objects may be placed within a distance
of 500 mm above the fireplace!
No combustible construction components, furniture, curtains or
decoration may be placed within a distance of 800 mm of the fire-
box door in the thermal radiation field (Fig. 8a – 8f). This distance
can be reduced to 400 mm when a thermal radiation protection
plate ventilated on both sides is installed between the fireplace and
the combustible elements.
If installed in the corner of a room, the CUBO or the PIKO may not
be rotatable. If the stove is assembled as shown in figure 8d, a
minimum clearance distance of 150 mm is to be maintained at
the sides. If wall coverings made out of combustible materials and
without thermal radiation protection have been fitted, the clearance
distance to the side is to be increased from 150 mm to 370 mm. If
the stove is assembled as shown in figure 8e, a minimum clearance
distance to the rear of 100 mm and to the side of 345 mm must
be maintained. If wall coverings made out of combustible materi-
als and without thermal radiation protection have been fitted, the
clearance distance to the side is to be increased from 345 mm to
735 mm. If the stove is assembled with a wood storage compart-
ment as shown in figure 8f, a minimum clearance distance to the
rear of 100 mm and to the side of 50 mm must be maintained. If no
wall coverings made out of combustible materials and without ther-
mal radiation protection have been fitted, the clearance distance to
the rear is to be increased from 100 mm to 250 mm.
FOR FLOOR COVERINGS NEAR TO THE STOVE:
Floor coverings made out of combustible materials in front of the
firebox opening of your CUBO / PIKO are to be protected with a sep-
arate covering made out of non-combustible construction materials.
The covering must extend at the front by at least 500 mm and at
each side by at least 300 mm (Fig. 8e and 8f) (measured from the
firebox opening or the glass panel)!
If the stove has a rotary function, the clearance distance in the
thermal radiation field and the protected floor covering area in front
of the firebox opening must be guaranteed in every possible rotat-
able position. In addition, the flue pipes must be fitted in such a way
that no negative influences are placed on the fixing of the stove.
The exhaust gas pipe may not rotate with the stove.
The minimum clearance distances to combustible construction ma-
terials and furniture are provided on the stove type plate and the
clearance distances may not fall below these levels.
Wallpaper as a wall covering is not classed as combustible con-
struction materials according to DIN 4102-1.
Observe the minimum clearance distance from the chimney flue pipes
to the combustible construction materials (see 2.2.5 Flue pipes).
GB 22