In general, a distance to the wall of at least 50 mm must be main-
tained. For safety reasons and for the purposes of fire protection,
larger clearance distances must be ensured for walls needing pro-
tection or for combustible construction materials.
A minimum distance of 100 mm (Fig. 6a, 6d) is to be maintained
between construction materials, furniture, decoration or curtains to
the rear of the stove. If the stove is rotatable, a minimum distance
of 420 mm (Fig. 6b) is to be maintained to guarantee sufficient
thermal protection. If wall coverings made out of combustible mate-
rials and without thermal radiation protection have been fitted, the
clearance distance to the rear is to be increased from 420 mm to
840 mm (Fig. 6b).
No combustible construction components, furniture, curtains or
decoration may be placed within a distance of 860 mm of the fire-
box door in the thermal radiation field (Fig. 6a – 6d). This distance
can be reduced to 420 mm when a thermal radiation protection
plate ventilated on both sides is installed between the fireplace and
the combustible elements.
If installed in the corner of a room, the PASSO M may not be rotat-
able. If the stove is assembled as shown in figure 6c, a minimum
clearance distance of 235 mm is to be maintained at the sides. If
wall coverings made out of combustible materials and without ther-
mal radiation protection have been fitted, the clearance distance to
the side is to be increased from 235 mm to 515 mm. If the stove
is assembled as shown in figure 6d, a minimum clearance distance
to the rear of 100 mm and to the side of 420 mm must be main-
tained. If wall coverings made out of combustible materials and
without thermal radiation protection have been fitted, the clearance
distance to the side is to be increased from 420 mm to 840 mm.
FOR FLOOR COVERINGS NEAR TO THE STOVE:
Floor coverings made out of combustible materials in front of the
firebox opening of your PASSO M are to be protected with a sepa-
rate covering made out of non-combustible construction materials.
The covering must extend at the front by at least 500 mm and at
each side by at least 300 mm (Fig. 6e) (measured from the firebox
opening or the glass panel)!
If the stove has a rotary function, the clearance distance and thus
the protected floor covering area in the thermal radiation field in
front of the firebox opening must be guaranteed in every possible
rotation position. In addition, the flue pipes must be fitted in such
a way that no negative influences are placed on the fixing of the
stove. The exhaust gas pipe may not rotate with the stove.
The minimum clearance distances to combustible construction ma-
terials and furniture are provided on the stove type plate and the
clearance distances may not fall below these levels.
Wallpaper as a wall covering is not classed as combustible con-
struction materials according to DIN 4102-1.
Observe the minimum clearance distance from the chimney flue
pipes to the combustible construction materials (see 2.2.5 Flue
pipes).