In general, a distance to the wall of at least 50 mm must be main-
tained. For safety reasons and for the purposes of fire protection,
larger clearance distances must be ensured for walls needing pro-
tection or for combustible construction materials.
A minimum distance of 100 mm (Fig. 3a) is to be maintained be-
tween construction materials, furniture, decoration or curtains to
the rear of the stove. If the stove is rotatable, a minimum distance
of 470 mm to the rear (Fig. 3b) is to be maintained to guarantee
sufficient thermal protection! If wall coverings made out of combus-
tible materials and without thermal radiation protection have been
fitted, the clearance distance to the side is to be increased from
470 mm to 855 mm. No combustible objects may be placed within
a distance of 500 mm above the fireplace.
No combustible construction components, furniture, curtains or
decoration may be placed within a distance of 1100 mm of the firebox
door in the thermal radiation field (Fig. 3a – 3f). This distance can
be reduced to 550 mm when a radiation protection plate ventilated
on both sides is installed between the fireplace and the combustible
construction elements (please read more about this in the FeuVo
and DIN 18896).
If installed in the corner of a room, the SENSO L may not be rotat-
able. If the stove is assembled as shown in figure 3c, a minimum
clearance distance of 130 mm is to be maintained at the sides. If
the stove is assembled as shown in figure 3d, a minimum clearance
distance to the rear of 100 mm and to the side of 470 mm must be
maintained. If wall coverings made out of combustible materials and
without thermal radiation protection have been fitted, the clearance
distance to the side is to be increased from 470 mm to 670 mm.
If the stove is assembled as shown in figure 3e, a minimum clear-
ance distance to the rear of 100 mm and to the sides of 130 mm
must be maintained. If the side walls are longer than 710 mm, then
figure 3d is valid.
FOR FLOOR COVERINGS NEAR TO THE STOVE:
Floor coverings made out of combustible materials in front of the
firebox opening of your SENSO L are to be protected with a covering
made out of non-combustible construction materials. The covering
must extend at the front by at least 500 mm and at each side by at
least 300 mm (Fig. 3f) (measured from the firebox opening or the
glass panel)!
If the stove has a rotary function, the clearance distance and thus
the protected floor covering area in the thermal radiation field in
front of the firebox opening must be guaranteed in every possible
rotation position. In addition, the flue pipes must be fitted in such
a way that no negative influences are placed on the fixing of the
stove. The exhaust gas pipe may not rotate with the stove.
The minimum clearance distances to combustible construction ma-
terials and furniture are provided on the stove type plate and the
clearance distances may not fall below these levels.
Wallpaper as a wall covering are not classed as combustible con-
struction materials according to DIN 4102-1.
Observe the minimum clearance distance from the chimney flue
pipes to the combustible construction materials (see 2.2.5 Flue
pipes).
GB 12