Herunterladen Diese Seite drucken

Lenze 8200 vector Montageanleitung Seite 148

Vorschau ausblenden Andere Handbücher für 8200 vector:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Show/Hide Bookmarks
Fault detection and elimination
8
Faulty drive behaviour
Fault
Motor parameter identification
Motor parameter identification
stops with error LP1
Unacceptable drive response
with vector control
Torque dip in the field weakening
range
Stalling of the motor when
operating in the field weakening
range
148
Cause
Motor too small compared with rated power
DC brake active via terminal
various
various
EDK82EV113 DE/EN/FR 5.0
Remedy
Vector control optimisation ( ^ 124)
Contact Lenze
L

Werbung

loading