Technical Data
Inverter output
Continuous output power P
Maximum surge power (3 s) P
Output voltage range
Output frequency
Output waveform
Distortion THD
Nominal input voltage
Input voltage range
Peak efficiency
Standby power consumption
No load power consumption [ASB]
Charger
Input voltage range
Input frequency range
Maximum charging current
Charging voltage (bulk/ float at 25 °C)
Auxiliary charging output
Nominal battery voltage
Recommended battery capacity
AC transfer switch
Maximum continuous current
Switching time
General technical data
Protection class
Ambient temperature for operation
Ambient temperature for storage
Ambient humidity
Dimensions (W x D x H)
Weight
Inspection/certification
EN
nom
surge
4445103626
MT ICC 1600 SI-N
1600 W
2500 W
230 Vw ± 2 %
50 Hz ± 0.05 %
Pure sine wave
THD ≤5 % at P
nom
12 Vg (± 3 %)
10 – 16.5 V
92 %
90 mA at 13 V
<10 W [2.0 W]
185 – 270 Vw
45 –65 Hz
60 A
14.4 V/ 13.2 V
–
12 Vg
200 –300 Ah
16 A
rms
0 – 5 ms
–20 °C to +50 °C
–40 °C to +80 °C
≤ 95 %, non-condensing
351 x 210 x 114 mm
10.7 kg
MT ICC 3000 SI-N
3200 W
5000 W
(Resistive load)
113 mA at 13 V
<20 W [3.5 W]
120 A (4 A)
4 A
12 Vg
400 Ah
32 A
rms
I
370 x 431 x 132 mm
19.0 kg