Setting the continuous mode
In continuous mode the inverter operates inde-
pendently of the load at the AC output (recom-
mended for small loads < 25 W).
1. Press the operating mode selection button
(see chapter "Remote control" on page 18) to
set automatic mode in inverter operation.
2. Press and hold the operating mode selection
button for at least 3 seconds to set to continu-
ous mode in inverter operation.
Activating charge equalization
(only for lead acid batteries)
During charge equalization the battery is charged
to 15.5 V at reduced output current.
A
NOTICE! Damage hazard
• Only carry out charge equalization on
lead-acid batteries.
• Disconnect all loads connected to the
battery during charge equalization.
• Observe the exact acid level of the bat-
tery during the entire process. Stop
charge equalization as soon as the acid
level is in accordance with the techni-
cal data provided by the manufacturer.
I
NOTE
• Charge equalization can only be car-
ried out if the charging program for
lead acid batteries is set (see chapter
"Setting the charging program" on
page 23) and the device is in trickle
charging phase.
• By safety timer the device ends charge
equalization after 2 hours and switches
back to trickle charging phase. If nec-
essary, activate the charge equaliza-
tion again.
1. Press and hold the equalize switch (fig. b 2,
page 8 and fig. f 2, page 10) for at least
3 seconds to activate charge equalization.
✔ All state of charge indication LEDs flash.
2. Press the equalize switch to stop charge equal-
ization.
✔ The device switches back to trickle charging
phase.
EN

Cleaning and maintenance

!
WARNING! Electrocution hazard
Unplug the device from the power sup-
ply before cleaning and maintenance.
A
NOTICE! Damage hazard
• Never clean the device under running
water or in dish water.
• Do not use sharp or hard objects, abra-
sive cleaning agents or bleach during
cleaning as these can damage the
device.
➤Occasionally clean the device with a soft, damp
cloth.
➤Regularly check live cables or lines for insulation
faults, breaks or loose connections.