Reifendruck-kontrollsystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
97-03 allMS RV_MTPM-200.qxm
Once all three alarm cycles have been gone through, the third alarm cycle is constantly
repeated until the correct pressure is restored. During each alarm cycle, the current
pressure of the tyre concerned is shown on the display
Should the alarm have been triggered by the spare tyre, the tyre symbol for excess-
pressure alarm flashes for 15 seconds and the symbol for the spare wheel. Additionally,
an acoustic alarm is triggered for 15 seconds, and the momentary pressure is displayed
for 15 seconds. If the pressure figures for the remaining four tyres are okay, the four
symbols are shown and the spare wheel symbol flashes. After 1 minute, the background
lighting is switched off.
Please note! Should the pressure value stabilise during the three alarm phases,
the next alarm phase is no longer executed.
Excess-temperature alarm
Triggering:
Display:
Once all three alarm cycles have been gone through, the third alarm cycle is constantly
repeated until the correct pressure is restored.
During each alarm cycle, the current temperature of the tyre concerned is shown on the
display.
The excess-temperature alarm is not triggered for the spare tyre.
Please note! Should the temperature stabilise during the three alarm phases,
the next alarm phase is no longer executed.
15.07.2003
How it works
The tyre temperature of the tyre shown has exceeded a temperature of
85 °C. The alarm is given in three stages.
1. The LCD display shows the temperature symbol (see Display), in ad-
dition the tyre concerned flashes for 2 minutes and an acoustic signal
sounds for 15 seconds. The optical and acoustic signals are emitted
at a frequency of approx. 1 Hz. Press the Check key on the display
to switch off the acoustic warning for the triggered alarm at any time.
2. The LCD display shows the temperature symbol (see Display), in ad-
dition the tyre concerned flashes for 2 minutes and an acoustic signal
sounds for 15 seconds. The optical and acoustic signals are emitted
at a frequency of approx. 2 Hz. Press the Check key on the display
to switch off the acoustic warning for the triggered alarm at any time.
3. The LCD display shows the temperature symbol (see Display), in ad-
dition the tyre concerned flashes for 2 minutes and an acoustic signal
sounds for 15 seconds. The optical and acoustic signals are emitted
at a frequency of approx. 4 Hz. Press the Check key on the display
to switch off the acoustic warning for the triggered alarm at any time.