Herunterladen Inhalt Inhalt Diese Seite drucken

Waeco magic control Typ MTPM-200 Montage- Und Bedienungsanleitung Seite 43

Reifendruck-kontrollsystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
97-03 allMS RV_MTPM-200.qxm
Once all three alarm cycles have been gone through, the third alarm cycle is constantly
repeated until the correct pressure is restored. During each alarm cycle, the current
pressure of the tyre concerned is shown on the display.
Should the alarm have been triggered by the spare tyre, the tyre symbol for pressure-loss
alarm 2nd stage flashes and the symbol for the spare wheel. Additionally, an acoustic
alarm is triggered for 15 seconds, and the momentary pressure is displayed for 15 sec-
onds. If the pressure figures for the remaining four tyres are okay, the four symbols are
shown and the spare wheel symbol flashes. After 1 minute, the background lighting is
switched off.
Please note! Should the pressure value stabilise during the three alarm phases,
the next alarm phase is no longer executed.
Excess-pressure alarm
Triggering:
Display:
15.07.2003
How it works
3. The LCD display shows the symbol (see Display) for pressure-loss
alarm 2nd stage, in addition the tyre concerned flashes for 2 minutes
and an acoustic signal sounds for 15 seconds. The optical and
acoustic signals are emitted at a frequency of approx. 4 Hz. Press
the Check key on the display to switch off the acoustic warning for
the triggered alarm at any time.
The tyre pressure of the tyre shown has increased 50 % or more over
the stored mean pressure value of the axle concerned. The alarm is
given in three stages.
1. The LCD display shows the symbol (see Display) for the excess-pressure
alarm, in addition the tyre concerned flashes for 2 minutes and an
acoustic signal sounds for 15 seconds. The optical and acoustic signals
are emitted at a frequency of approx. 1 Hz. Press the Check key on the
display to switch off the acoustic warning for the triggered alarm at any
time.
2. The LCD display shows the symbol (see Display) for the excess-pressure
alarm, in addition the tyre concerned flashes for 2 minutes and an
acoustic signal sounds for 15 seconds. The optical and acoustic signals
are emitted at a frequency of approx. 2 Hz. Press the Check key on the
display to switch off the acoustic warning for the triggered alarm at any
time.
3. The LCD display shows the symbol (see Display) for the excess-pressure
alarm, in addition the tyre concerned flashes for 2 minutes and an
acoustic signal sounds for 15 seconds. The optical and acoustic signals
are emitted at a frequency of approx. 4 Hz. Press the Check key on the
display to switch off the acoustic warning for the triggered alarm at any
time.