5.5.1
Object modes – adjusting the brightness of the image
The object modes are customized for different materials of the respective objects:
en
For the object modes S, C, M, image processing is performed internally, improving the image
quality with respect to reflections and color reproduction.
Different parameters are stored for each object mode, including the individual image brightness. This can
be changed�
To do so:
⇒ Select the object mode to be modified (see Chapter 5.5).
⇒ Press the mouse wheel (B)�
♦ A setting bar appears, where the current image brightness is displayed�
⇒ Turn the mouse wheel to change the brightness�
♦ Darker
♦ The "zero position" corresponds to the factory setting�
5.6
Screen shot / still image
Using the foot switch, the monitor image can be frozen (still image) or also stored on the USB memory
stick (screen shot)�
5.6.1
Still image
⇒ Press the foot switch for more than 1 sec�
♦ The still image is displayed, meaning the monitor image is frozen�
While the still image is displayed, the following actions can be performed:
⇒ Briefly press the foot switch.
♦ The screen contents are saved to the USB stick as a screen shot (see Chapter 5�6�2)�
⇒ Press the foot switch for more than 1 sec�
♦ Switch back to the live image�
The following settings can be changed while the still image is displayed:
• Switch between 2D and 3D display�
• Switch of magnification between 15x and 20x.
5.6.2
Saving a screen shot
Screen shot are only saved as 2D images, even if the 3D display was set when the save operation was
performed�
⇒ Briefly press the foot switch.
♦ The screen contents are saved to the USB stick as a screen shot�
♦ The screen shot icon appears on the monitor�
♦ The file name is displayed on the monitor during the save operation.
♦ No other actions are possible during the save operation (approx� 5 sec�)�
Ceramic
Metal
Standard (for example, when working with dentures, waxes, etc�)
Neutral (especially for delicate, detailed areas and transitions in crowns and bridges)
For using the UV filter / composite (see accessories).
Currently not used�
Brighter