3. Top up the oil mist lubricator with fresh oil to the
maximum level.
13.4.4
Changing the oil in the oil mist lubricator
1. Remove the compressed-air connection.
2. Unscrew the container on the oil mist lubricator.
3. Drain and dispose of the oil.
4. Top up with fresh oil.
13.4.5
Setting the lubricating oil flow
1. Unscrew the container on the oil mist lubricator.
2. Use a screwdriver to set the screw indicated by the
arrow in such a way that 1 drop of oil emerges for
every 3 opening and closing operations of the flange.
13.5
Diagnostics
i
The diagnostics menu is used for maintenance
carried out by customer service. The user has no
access to any of the menu functions but can call up
the statuses of the elements displayed.
Beissbarth GmbH
Maintenance | MT ZERO 6 Touch | 145
1. Open the diagnostics menu on the "Home" main
screen.
Fig. 127: Calling up the diagnostics menu
2. Enter and confirm the password 2857.
 The diagnostics screen intended for the operator
will be displayed.
Fig. 128: Operator diagnostics page
Symbols
Description
After a tap on the symbol, the "Home" main screen
will be shown again.
Green stop light: the component has no
malfunctions.
Red stop light: malfunctions have been found on
the component. Contact customer service.
13.6
Calibration
i
As part of service and upkeep (every six months), on
flange replacement or in the event of measurement
inaccuracies, it is advisable to calibrate the
MT ZERO 6 Touch in the following sequence:
1. Calibrate the flange.
2. Calibrate the electronic rim distance gauge and the
sonar probe.
3. Use a wheel and a balance weight for calibration.
4. Perform a reference measurement.
5. Calibrate the external laser indicator.