Some machine versions require the wheel to be
positioned manually according to the instructions
shown on the monitor.
!
The calibration process must be repeated in the
following cases:
$
Error of the intentionally added imbalance
exceeding 5 g.
$
Deviation from the position of the specified
imbalance (balance weight not between the 5:30
and 6:30 positions).
7. Remove the balance weight.
8. Release the wheel, and rotate it by approx. 90°.
9. Secure the wheel again.
10. Close the wheel guard.
 The measurement will start.
"
After this reference measurement, the imbalance
displayed must not exceed 10  g per side (15  g for
particularly heavy wheels). The error may result
from the rim centering tolerances. If the reference
measurement indicates a greater imbalance, check the
components used for centering the wheel for wear, play
and contamination.
Beissbarth GmbH
Maintenance | MT ZERO 6 Touch | 149
13.6.6
External laser indicator calibration
i
The calibration plate is required for the calibration.
i
The laser will only switch on if the wheel comes to a
stop at the position for attaching the clip-on balance
weight.
Remove the cover of the sonar probe.
Fig. 135: Removing the cover of the sonar probe
The following describes 2 different procedures: one
for the mechanical version and one for the pneumatic
version.
Mechanical version
1. Remove any dirt on the flange with a wire brush.
2. Place the calibration plate included in the scope of
delivery against the flange's surface.
3. Lock the calibration plate by using a quick-clamping
ring and by inserting a small cone.
!
Make sure the calibration plate is centered relative
to the flange shaft.
Fig. 136: Attaching the calibration plate
en
12
6
|
1 695 600 965
2020-02-27