Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch Rexroth PSI 6 Serie Betriebsanleitung Seite 403

Schweißsteuerung mit mittelfrequenz-umrichter
Vorschau ausblenden Andere Handbücher für Rexroth PSI 6 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1070080028 / 08
|
PSI 6xxx
When loading has been completed, the system will display the new
firmware version loaded in the "SST" field.
If the firmware is generally suitable for the timer, the background of
the "SST" field will be green, otherwise it will be red.
Only suitable firmware versions can be programmed into the timer's
flash memory in the course of the process.
If activated (refer to step 4.: "Save Counter", "Backup", "UIR Backup"
7.
options) the relevant data will be automatically saved on the pro­
gramming terminal.
During this process, the message "Backup" will be displayed in the
"Status" field.
Interruption of power supply
Possibility of damage to the unit!
"
When the next step has been initiated, the power supply must not
be interrupted until the complete firmware has been loaded.
If "Change after Load" has been activated (refer to step 4.), repro­
8.
gramming of the flash memory is automatically initiated in the timer.
If the option has not been activated, you can start reprogramming
with the "FW Change" command button.
While the flash memory is reprogrammed, the timers involved
• cannot be used for welding tasks,
• are not "Ready".
As soon as programming starts, the "Wait" window will be displayed.
Wait until the "Wait" window is automatically closed (duration: ap­
prox. 100s).
When programming has been completed (duration: approx. 60s), an
automatic Reset will cause the timer to be rebooted.
If activated (refer to step 4.: "Save Counter", "Backup" options) the
9.
data backed up in step 7. will be automatically restored from the pro­
gramming terminal to the timer.
During this process, the message "Restore" will be displayed in the
"Status" field.
Make sure that the firmware update was properly carried out for all
10.
selected timers.
Click on the "List" command button. All currently active firmware ver­
sions are displayed in the new "SW Version" window that is now dis­
played.
Then close the "SW Version" window and the "FWUpdate" software.
A firmware version loaded into the dedicated RAM memory range of
the timer can also be displayed in the "SST"
field using the "Dsp.FW" command button.
'weld timer')
The data of a timer that was saved last can also be manually restored
to the timer using the "Bkup+Ctr->SST" command button without in­
voking the procedure described above.
Bosch Rexroth AG
Service and repair
NOTICE
(German abbreviation of
403 / 460

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis