E/A Disk R2Ed" And "E/A Disk R4Ed" I/O Module; Table 9: Technical Data: "E/A Disk R2Ed" / "E/A Disk R4Ed" I/O Module - Bosch Rexroth PSI 6 Serie Betriebsanleitung

Schweißsteuerung mit mittelfrequenz-umrichter
Vorschau ausblenden Andere Handbücher für Rexroth PSI 6 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

292 / 460
Bosch Rexroth AG
Information on this product
5.2.4.9
"E/A DISK R2ED" and "E/A DISK R4ED"
Voltage supply
I/O module
Features:
• 26 discrete inputs (24 V
• 1 output as switched relay (1 x ON)
• 18 discrete outputs (24 V
Function:
• Coupling of discrete I/O signals.
The I/O modules EA DISK R2ED and EA DISK R4ED are identical
except for the connector designations (EA DISK R2ED: X1x; EA
DISK R4ED: X2x) and an internal coding.
If both are used in a WT, the I/O signals used are permanently cou­
pled to the respective module. That is why all I/O signals always ap­
pear at the same I/O module even after exchanging the slots of both
modules.
Table 9:
Technical data: "E/A DISK R2ED" / "E/A DISK R4ED" I/O mo­
dule
Operating voltage
Power input
Power loss
Signal inputs
Signal outputs
Fusing of signal out­
puts
Connection:
E/A DISK R2ED: X10: 4-pole
E/A DISK R4ED: X20: 4-pole
STKK, grid 3.5 mm, max. 1.5 mm
Mating connector is comprised in the delivery.
Cable length:
(from power source to consumer)
max. 10 m at 0.75 mm
max. 75 m at 1.5 mm
Cable type:
unshielded, VDE 0281, 0812 (e.g.: Ölflex)
PSI 6xxx |
)
DC
)
DC
+24 V= +20 %, -15 %
with max. +/-5 % ripple
max. 2 A
subject to circuitry connected to the signal inputs/
outputs
0.5 VA per active input
2.4 VA per active output
logic 1: +16 V ... +30 V, 20 mA
logic 0: -1 V ... +4 V
O0, O13...O15:
+24 V, max. 0.7 A
(for solenoid and prelift valves)
O1...O10, O12, O16...O18: +24 V, max. 0.1 A
O11: +24 V, max. 0.2 A
(floating relay contact)
electronic