Bosch Rexroth AG
Information on this product
5.2.3.1

Partial front-panel view PSI 6x00.xxx

LOGIC LED; green. Is on when 24 V
power supply) is available.
DC LINK CIRCUIT LED; red (only operative if LOGIC LED is illumina­
ted in green).
Is on if DC link voltage is present.
READY LED; green. Is on if no error is present in the timer. The
unit is ready for welding.
WELD TIME LED; yellow. Is on while the power unit is activated.
BATTERY FAULT LED; red. Is on if a new battery is to be inserted
(refer to page 396).
RESET button. Returns the timer to READY state when a fault has occur­
red (and has been corrected).
DIP switch. Function depends on timer type.
Boot LED; red. Is on while the timer is in "Boot" mode.
"Boot" key for calling up the "Boot" mode. Required for a firmware upgrade
in connection with the "WinBlow" software (refer to page 399). Welding is
not possible in "Boot" mode. Exiting Boot mode: Toggle 24 V logic voltage
off / on.
V24 connection to programming terminal (for programming on location).
Refer to Sect. 7.2.5 from page 363.
24 V
output for power supply to I/O module (refer to page 367).
DC
24 V
output of the internal voltage source (refer to page 366).
DC
24 V
input for logic power supply (refer to page 365).
DC
Terminals for 24 V
voltage distribution (refer to page 368).
DC
Temperature-controlled 24 V
fans (refer to page 372).
24 V
output, e.g. for power supply to external consumers.
DC
Refer to Sect. 7.2.11 on page 373.
Terminals for "Main switch release" (refer to page 382)
Type-dependent: Analog output for force actuating variable. Refer to Sect.
7.2.12 from page 374.
Type-dependent: Digital (24 V
feedback. Refer to Sect. 7.2.13 from page 375.
Type-dependent: Output for "Operate" signal output.
Type-dependent: Analog input for (force) feedback. Refer to Sect. 7.2.13 from
page 375.
Type-dependent: 0 V reference for output "Operate".
Measuring input for secondary current measurement.
Refer to Sect. 7.2.14 on page 377.
Type-dependent: Output/input for monitoring the transformer temperature
(refer to Sect. 7.2.15 on page 380).
Battery for buffering the unit's internal RAM (for replacement of battery,
please refer to page 396).

Fig. 7:Partial front-panel view PSI 6x00.xxx

(logic
DC
supply output for the supply/control of external
DC
) and analog (0..10 V
) input for (force)
DC
DC
PSI 6xxx |
1070080028 / 08