Miniature fuse M 1.6 A; for fusing the outputs O0 and O13 to O15
-
Miniature fuse M 1.6 A; for fusing the outputs O1 to O10
-
Signal inputs I0 to I13 (24 V
-
2x voltage output for power supply to the ext. input
circuits (internally tapped from X10)
-
Signal inputs I14 to I20 (24 V
-
1x voltage output for power supply to the ext. input
circuits (internally tapped from X10)
-
Signal outputs, with control LED
O0...O10 and O13...O15: (24 V
O11...O12: floating relay contact, max. 0.2 A
-
0 V reference potential of the 24 V
(internally tapped from X10)
-
Power supply to the I/O module (24 V
Terminals 1 and 3 linked internally
Terminals 2 and 4 linked internally

Fig. 21: Front panel view: "E/A DISK 2R" / "E/A DISK 4R" I/O module

), with control LED
DC
), with control LED
DC
);
DC
signal outputs
DC
)
DC
The I/O ‐modules EA DISK R2ED and EA DISK R4ED are identical
except for the connector designations (EA DISK R2ED: X1x; EA
DISK R4ED: X2x) and an internal coding.