1070080028 / 08
|
PSI 6xxx
5.2.4.12
"E/A IBS OPC with optical fiber" (INTERBUS-S) I/O module
Ident. code 229
Ident. code 47
Only in combination with PSI 6x00.xxx.
Features:
• 8 discrete inputs (24 V
• 8 discrete outputs (24 V
• INTERBUS-S connection via optical fiber
• Networking with programming terminal (BOS) possible via PLC ma
ster
Function:
• Linking the timer's I/Os to the higher-level PLC or the robot
• via INTERBUS-S and an optical fiber at X12 to X15 (serial I/Os)
and
• via discrete 24 V signals at X11 (parallel I/O).
• transparent networking of the timer using the optical fiber ports.
Whether or not the INTERBUS-S connection is used for networking the
timer can be set on the ADR dip switch (timer front panel). The following
applies:
• all switches in "off" position:
Both the I/O data exchange and networking is handled by the mo
dule. The timer responds as an INTERBUS-S drop with the decimal
ident. code 229.
The programming terminal (BOS) is linked to the PLC via an Ether
net port in this application variety which "tunnels" data traffic with the
connected weld timers via INTERBUS-S.
• at least 1 switch in "on" position:
Only I/O data exchange is handled by the module. The timer re
sponds as an INTERBUS-S drop with the decimal ident. code 47.
Networking with the programming terminal (BOS) is achieved using
the Ethernet module in the field bus slot (refer to page 276).
Table 12:
Technical data: "E/A IBS OPC with optical fiber" I/O module
Operating voltage
Power input
Power loss
Signal inputs
Signal outputs
Bosch Rexroth AG
Information on this product
)
DC
)
DC
+24 V= +20 %, -15 %
with max. +/-5 % ripple
max. 2 A
subject to circuitry connected to the signal inputs/
outputs
0.5 VA per active input
2.4 VA per active output
logic 1: +16 V ... +30 V, 20 mA
logic 0: -1 V ... +4 V
+24 V, max. 0.1 A , short-circuit-proof
301 / 460