Herunterladen Inhalt Inhalt Diese Seite drucken

Measuring Input For Secondary Voltage Measurement; Fig. 83: With Psi 6X00.Xxx: Connection For Secondary Voltage Measurement; Fig. 84: With Psi 6Xcx.xx: Connection For Secondary Voltage Measurement - Bosch Rexroth PSI 6 Serie Betriebsanleitung

Schweißsteuerung mit mittelfrequenz-umrichter
Vorschau ausblenden Andere Handbücher für Rexroth PSI 6 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

384 / 460
Bosch Rexroth AG
Assembly
7.2.17

Measuring input for secondary voltage measurement

In connection with PSI 6x00.xxx
In connection with PSI 6xCx.xxx
This function is only available if the "UI Regulation" option has been
activated!
The detailed documentation, part no. 1070087072, is available on
UI regulation/monitoring.
Connection:
to X8A of the PSQ 6000 XQR module
(refer to page 317);
STKK, grid 3.5 mm, 4-pole,
max. 1.5 mm
Mating connector is comprised in the delivery.
Cable length:
max. 100 m (with recommended cable type)
Cable type:
shielded, core area min. 0.75 mm
(e.g.: 2 x 2 x 0.75 mm
Order no.: 1070 913 494)
X8A
Voltage input
1
2
Shield
3
Voltage input
4
Shield
Shield connection to terminal 4 of X8A !
Fig. 83: With PSI 6x00.xxx: Connection for secondary voltage measure­
ment
Connection:
to X3; STKK, grid 3.5 mm, 8-pole,
max. 1.5 mm
Mating connector is comprised in the delivery.
Cable length:
max. 100 m (with recommended cable type)
Cable type:
shielded, core area min. 0.75 mm
(e.g.: 2 x 2 x 0.75 mm
Order no.: 1070 913 494)
X3
6
Voltage input
7
Voltage input
8
Shield
Shield connection to terminal 3 of X8 !

Fig. 84: With PSI 6xCx.xx: Connection for secondary voltage measurement

PSI 6xxx |
2
.
2
LiYCY,
D
Secondary circuit
2
.
2
LiYCY,
D
Secondary circuit
1070080028 / 08
2
,
2
,

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis