Herunterladen Inhalt Inhalt Diese Seite drucken

Reset And Factory Settings; General System Reset; Factory Settings; Restoring The Factory Settings - DAB e.sybox Bedienungs- Und Wartungsanweisung

Vorschau ausblenden Andere Handbücher für e.sybox:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 114

10. RESET AND FACTORY SETTINGS

10.1 General system reset

To reset the system, hold down the 4 keys simultaneously for 2 sec. This operation is the same as disconnecting the power, waiting for it to close down
completely and supplying power again. The reset does not delete the settings saved by the user.

10.2 Factory settings

The device leaves the factory with a series of preset parameters which may be changed according to the user's requirements. Each change of the settings
is automatically saved in the memory and, if desired, it is always possible to restore the factory conditions (see Restoring the factory settings par 8.3 –

Restoring the factory settings).

10.3 Restoring the factory settings
To restore the factory values, switch off the device, wait until the display has switched off completely, press and hold down the "SET" and "+" keys and
turn on the power; release the two keys only when the letters "EE" appear. This restores the factory settings (a message and a rereading on EEPROM of
the factory settings permanently saved in the FLASH memory). Once all the parameters have been set, the device returns to normal operation.
NOTE: Once the factory values have been restored it will be necessary to reset all the parameters that characterise the system (gains, setpoint pressure,
etc.) as at the first installation.
Identifying
code
TK
LA
SP
Setpoint pressure [bar]
P1
P2
P3
P4
RI
Revs per minute in manual mode [rpm]
OD
RP
Pressure decrease to restart [bar]
AD
PR
Remote pressure sensor
MS
TB
Blockage time for water lack [s]
T1
Low pr. delay (KIWA) [s]
T2
Delay in switching off [s]
GP
Proportional gain coefficient
GI
Integral gain coefficient
RM
NA
NC
IC
Configuration of the reserve
ET
Max. switching time [h]
AE
AF
I1
I2
I3
I4
O1
O2
PW
AY
Anticycling Function AY
Factory settings
Description
Backlight lighting T
Language
Setpoint P1 [bar]
Setpoint P2 [bar]
Setpoint P3 [bar]
Setpoint P4 [bar]
Type of plant
Address configuration
Measuring system
Maximum speed [rpm]
Active devices
Simultaneous devices
Anti-blocking function
Antifreeze
Function I1
Function I2
Function I3
Function I4
Function output 1
Function output 2
Change Password
ENGLISH
Value
Installation Memo
2 min
ENG
3,0
2,0
2,5
3,5
4,0
2400
1 (Rigid)
0,3
0 (Auto)
Disable
0 (International)
15
2
10
0,5
1,2
3050 per e.sybox
N
NA
1 (Auto)
2
1(Enable)
1(Enable)
0 (Disable)
0 (Disable)
0 (Disable)
0 (Disable)
2
2
0
0 (Disable)
64
Tabella 22: Impostazioni di fabbrica

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis