Setup of the outputs OUT1,
OUT2
Factory configurations of the outputs
Uscita
OUT 1
OUT 2
O1: Setting output 1 function Output 1 communicates an active alarm (it indicates that a system block has occurred). The output allows the use
O2: Setting output 2 function Output 2 communicates the motor running status. The output allows the use of a normally open clean contact.
Configuration of the functions associated with the outputs
Output
Activation
configuration
condition
No associated
0
function
No associated
1
function
Presence of
2
blocking errors
Presence of
3
blocking errors

FW: Firmware update

RF: Fault and warning reset

PW: Change password

Password for multipump systems

When the PW is typed in to unlock a device in a set, all the devices are unlocked. When the PW is changed on a device in a set, all the devices receive
the change. When activating protection with a PW on a device in a set (+ and – on page PW when PW≠0), the protection is activated on all the
devices (to make any change you are asked for the PW).
This section shows the functions and possible configurations of outputs OUT1 and OUT2 of the I/O control unit,
with wireless connection to the device, set by means of parameters O1 and O2.
For the electrical connections, refer to the control unit manual.
The factory configurations can be seen in Table 20.
Value
2 (fault NO closes)
2 (Pump running NO closes)
of a normally open clean contact. The values and functions indicated in Table 21 are associated with the
parameter O1.
The values and functions indicated in Table 20 are associated with the parameter O2.
OUT1
Output contact
Activation condition
status
Contact always
No associated
open
Contact always
No associated
closed
In the case of
Output activation in
blocking errors
the contact closes
blocking errors
In the case of
Output activation in
blocking errors the
contact opens
blocking errors
This menu page allows you to update the e.sybox firmware. For the procedure see chapter 13.
Holding down the + and – keys together for at least 2 seconds deletes the history of faults and warnings. The
number of faults present in the log is indicated under the symbol RF (max 64).
The log can be viewed from the MONITOR menu on page FF.
The device has a password-enabled protection system. If a password is set, the parameters of the device will be
accessible and visible but it will not be possible to change them. When the password (PW) is "0" all the parameters
are unlocked and can be edited. When a password is used (value of PW different from 0) all modifications are
blocked and "XXXX" is displayed on the page PW.
If the password is set it allows to navigate through all the pages, but at any attempt to edit a parameter a pop-up
appears, asking you to type in the password. When the correct password is typed in the parameters are unlocked
and can be edited for 10' after the last key is pressed.
If you want to cancel the password timer, just go to page PW and hold down + and – together for 2". When the
correct password is typed in a padlock is shown opening, while if the wrong password is given a flashing padlock
appears. After resetting the factory values the password is set back at "0".
Each change of the password takes effect when Mode or Set is pressed and each subsequent change of a
parameter implies typing in the new password again (e.g. the installer makes all the settings with the default PW
value = 0 and lastly sets the PW so as to be sure that the machine is already protected without any further action).
If the password is lost there are 2 possibilities for editing the parameters of the device:
– Make a note of the values of all the parameters, reset the device with the factory values, see paragraph 10.3.
The reset operation cancels all the parameters of the device, including the password.
– Make a note of the number present on the password page, send a mail with this number to your service centre,
in a few days you will be sent the password to unlock the device.
ENGLISH
Table 20: Factory configurations of the outputs
OUT2
Output contact status
Contact always open
function
Contact always closed
function
When the motor
case of
is running the contact
closes
When the motor
case of
is running the contact
opens
63
Table 21: Configuration of the
outputs