the system to load completely. You must survey the operation and close the loading door as soon as the water comes out (however it is
recommended to fit a check valve in the section of the suction pipe and to use it to control the loading operation with the cap open). Alternatively,
in the case where the suction pipe is intercepted by a closed valve, the loading operation may be carried out in a similar way to the one described
for installation over head.

4.2 Horizontal Configuration

Remove the 4 support feet from the bottom tray of the packaging and screw them fully into their brass seats on face E. Put the system in place,
taking into account the dimensions in Fig Fig.9.
– The distance of at least 270mm between Face B of the system and an obstruction is recommended so as to be able to carry out maintenance
on the non-return valve without disconnecting the system.
– The distance of at least 200mm between Face A of the system and an obstruction is recommended so as to be able to remove the door and
gain access to the technical compartment.
The distance of at least 10mm between Face D of the system and an obstruction is obligatory to let out the power supply cable
If the surface is not flat, unscrew the foot that is not touching and adjust its height until it contacts the surface so as to ensure the stability of the
system. The system must in fact be placed in a safe and stable position, ensuring that its axis is vertical: it must not be in an inclined position.

4.2.1 Hydraulic connections

Make the connection at input to the system through the mouth on Face C marked "IN" in Fig. 9 (suction connection). Then remove the respective
cap with the aid of the accessory tool or with a screwdriver.
Make the connection at output from the system through the mouth on Face C marked "OUT 1" in Fig. 9 and/or through the mouth on Face D
marked "OUT 2" in Fig. 9 (delivery connection). In this configuration either of the 2 mouths can be used as an alternative to the other (depending
on the convenience of the installation), or simultaneously (dual delivery system). So remove the cap(s) from the door(s) you intend to use with the
aid of the accessory tool or with a screwdriver.
All the hydraulic connections of the system to the plant to which it can be connected are of the threaded female type 1" GAS, made of brass.
See WARNING for Fig.8.

4.2.2 Orientation of the Interface Panel

The Interface Panel has been designed so that it can be oriented in the direction where it is most convenient for the user to read: its square shape
allows it to be rotated from 90° to 90° (Fig.10).
– Disengage the 4 screws at the corners of the panel using the hex wrench provided with the accessory tool.
– Do not remove the screws, just disengage them from the thread on the product body.
– Be careful not to drop the screws into the system.
– Move the panel away, taking care not to pull on the signal transmission cable.
– Reposition the panel in its seat at the preferred angle taking care not to pinch the cable.
– Tighten the 4 screws with the wrench.