7. RESET AND FACTORY SETTINGS

7.1 General system reset

To reset the system, hold down the 4 keys simultaneously for 2 sec. This operation is the same as disconnecting the power, waiting for it to close
down completely and supplying power again. The reset does not delete the settings saved by the user.

7.2 Factory settings

The device leaves the factory with a series of preset parameters which may be changed according to the user's requirements. Each change of
the settings is automatically saved in the memory and, if desired, it is always possible to restore the factory conditions (see Restoring the factory
settings par 7.3 - Restoring the factory settings).

7.3 Restoring the factory settings

To restore the factory values, switch off the device, wait until the display has switched off completely, press and hold down the "SET" and "˄" keys
and turn on the power; release the two keys only when the letters "EE" appear. This restores the factory settings (a message and a rereading on
EEPROM of the factory settings permanently saved in the FLASH memory). Once all the parameters have been set, the device returns to normal
operation.
NOTE: Once the factory values have been restored it will be necessary to reset all the parameters that characterise the system (gains, setpoint
pressure, etc.) as at the first installation.
Identifying code
BK
TK
LA
SP
RI
OD
RP
MS
EK
PK
TB
T1
T2
GP
GI
RM
AE
AF
PW
AY
Description
Display brightness
Backlight lighting T
Language
Setpoint pressure
Revs per minute in
manual mode
Type of plant
Pressure decrease to
restart
Measuring system
Low pressure function on
suction
Low pressure threshold
on suction
Blockage time for water
lack
Low pr. delay
Delay in switching off
Proportional gain
coefficient
Integral gain coefficient
Maximum speed
Anti-blocking function
Antifreeze
Change Password
Anticycling Function AY
ENGLISH
Factory settings
International factory
settings
80%
/ 50%
(1)
(2)
2 min
English
2,7 bar
3200 rpm
1 (Rigid)
0,3
0 (International)
1 (Enable)
1,0 bar
15 s
2 s
10 s
0,5
1,2
7000 rpm
1(Enable)
1(Enable)
0
0 (Disabled)
Table 13: Factory settings
57
Angloamerican factory
settings
80%
/ 50%
(1)
(2)
2 min
English
39 psi
3200 rpm
1 (Rigid)
0,3
0 (International)
1 (Enable)
4 psi
15 s
2 s
10 s
0,5
1,2
7000 rpm
1(Enable)
1(Enable)
0
0 (Disabled)