Grundfos Control MPC-Serie Installationsanleitung Seite 10

Vorschau ausblenden Andere Handbücher für Control MPC-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 75
Option
Dry-running
protection - inlet
pressure sensor
Dry-running
protection - digital
input
Fault light, pump
Operating light,
pump
Fault light, system
Operating light,
system
Ammeter
Voltmeter
Pilot pump control
Main switch with
door interlock
Main switch for
neutral conductor
Phase-failure
monitoring
Panel light and
socket
Transient-voltage
protection
10
Operating-panel options
Description
The inlet-pressure sensor is visible on
the wiring diagram.
-
Note: inlet-pressure switch not
included.
Digital input is visible on the wiring
-
diagram.
The fault light is on if a fault occurs in
the pump.
Note: One fault light for each pump.
The operating light when the relevant
pumps is in operation.
Note: One operating light for each
pump.
The fault light is on if a fault occurs in
the system.
Note: Phase failure causes no fault
indication.
The operating light is on when the
system is in operation.
An ammeter indicates the current of one
-
phase per pump.
Note: One ammeter for each pump.
A voltmeter indicates the mains
voltages between mains phases and
-
between the neutral conductor, N, and
the mains phases.
Note: One voltmeter for each pump.
With this option the Control MPC is
prepared for connection, meaning that it
-
includes fuses and motor starter. The
pilot pump is visible on the wiring
diagram.
The cabinet door can only be opened if
-
the main switch is in off position.
The main switch for switching off the
neutral conductor is only used in
connection with single-phase motors.
-
Select this option according to the local
rules for the installation site. As
standard, the main switch does not
switch off the neutral conductor.
Protect the booster system against
phase failure.
-
Note: A potential-free switch is
available for external monitoring
The panel light is on when the door of
the control cabinet is open.
Panel lights for 50 Hz are in accordance
-
with EN 60529/10.91.
Note: The panel light and socket are to
be connected to a separate power
supply.
The transient-voltage protection
-
protects the booster system against
high-energy transients.
Included in pre-
defined Control
MPC standard
Options
(type key
Location
A
for Control
MPC)
In the
control
O9
cabinet
In the
control
O10
cabinet
In door of
control
O11
-
cabinet
In door of
control
O12
-
cabinet
In door of
control
O13
-
cabinet
In door of
control
O14
-
cabinet
In door of
control
O15
-
cabinet
In door of
control
O16
-
cabinet
In the
control
O17
-
cabinet
In the
control
O18
-
cabinet
In the
control
O19
-
cabinet
In the
control
O20
-
cabinet
In the
control
O21
-
cabinet
In the
control
O22
-
cabinet
B
E
F
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-