STARTER RELAY OPERATION CHECK

7.5 STARTER RELAY OPERATION CHECK
WARNING! – Remove the cap of the sparking
plug, since the safety systems that normally pre-
vent accidental starting of the engine are cut out
when the checking procedure is carried out.
To do this requires:
– engaging the parking brake;
– disengaging the blade;
– the key in the «ON» position.
Disconnect the connector CN3.
In making a bridge between the terminals 2 and 4
(CN3) of the wiring connectors (1), the click of the
relay bobbin should be heard and the starter motor
should come into action.
If the relay clicks but the starter motor does not go,
make a bridge (2) with a large section cable (5 mm
between the power contacts of the relay.
If the starter motor comes into operation, look for
the fault within the relay or replace it. Otherwise,
check the starter motor together with its wiring.