Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23

MENU STRUCTURE

1. 1 Outdoor
1 . 2 F l o w
1 . 3 F l o w 2
1. Measu r ement
1.4 Sensor 4
1.5 Room
1.6 Room sensor
1.7 RC swit ch
1 . 8 Tar ge t f lo w
1 . 9 Tar ge t f lo w 2
2 . 1 To d a y
2 . 2 2 8 d a y s
2.3 Out door 876 0h
2. S t at is tics
2 . 4 F l o w 8 7 6 0 h
2.5 Op.hou r s H C
2.6 Op.hou r s DHW
2.7 Op.hou r s H C2
2.8 Op.hou r s H eat
2.9 Er r or messages
2.10 Rese t/Clear
3.1 T im e and dat e
3 . 2 D a y l i g h t S a v i n g
3.3 Heat ing cir cuit day
3. T ime s
3.4 Heat ing com f or t
3 . 5 H o t w a t e r e n a b l e
3 . 6 H o t w a t e r A L
4.1 Heat ing circ.
4.2 Manu al
4.3 Heat c irc uit re fere nce
4. Oper at in g mod e
4.4 14 day reference
4.5 Dom esti c hot water
5 . 1 S / W d a y
5.2 S/W ni ght
5 . 3 C u r v e
5 . 4 D a y c o r r e c t
5. HC se ttin gs
5.5 Night cor r e ct
5.6 Comf or t t emp boos t
5.7 Ref er enc e/actual -
5.8 Ref er enc e/actual +
6 . 1 S / W d a y
6.2 S/W ni ght
6 . 3 C u r v e
6. HC 2 se t t ing s
6 . 4 D a y c o r r e c t
6.5 Night cor r e ct
6.6 Comf or t t emp boos t
7.1 Hotwater minim um
7. DHW Settings
7.2 DH W target
7.3 DH W hyst eresis
8 . 1 F r o s t p r o t e c t i o n
8 . 2 M i n . f l o w
8. Pr o t ect ions
8 . 3 M a x . f l o w
8 . 4 M a x f l o w 2
8.5 Anti -l egi onella
9.1 Sensor calibr ation
9.2 Com issi oning
9 . 3 F a c t o r y s e t t i n g s
9. S pecial funct i o ns
9.4 Ex pan sions (n/a)
9.5 Mixer
9.6 Room sensor
9.7 Sy s t em
10. Menu Lock
10.1 Menu Lock
11. S er vice Dat a
12. Language
12
MEASUREMENTS, MENU 1
2.3.1 Cur r ent Year
2 . 3 . 2 P r e v i o u s Ye a r
2 . 3 . 3 2 y e a r s a g o
1. Exit measurements
2.4.1 Cur r ent Year
1.1 Outdoor
2 . 4 . 2 P r e v i o u s Ye a r
2 . 4 . 3 2 y e a r s a g o
1.2
F l o w
2.5.1 Op.hour s HC
2.5.2 Since
2.6.1 Op.hour s DHW
2.6.2 Since
2.7.1 Op.hour s HC 2
2.7.2 Since
2.8.1 Op.hour s HC he at
2.8.2 Since
1.1 Outdoor
2 . 1 0 . 1 To d a y
2 . 1 0 . 2 2 8 d a y s
2.10.3 Outdoor 87 60 h
current outdoor temperature
2 . 1 0 . 4 F l o w 8 7 6 0 h
2.10.5 Oper ating Ho ur s
2.10.6 Er r or me ssa g e s
2.10.7 All s t atis tics
3 .3 .1 .M o . - 3 .3 .7 Su
3 .4 .1 .M o . - 3 .4 .7 Su
3 .5 .1 .M o . - 3 .5 .7 Su
If "Error" appears on the display instead of the measurement value, then there
3 .6 .1 .M o . - 3 .6 .7 Su
may be a defective or incorrect temperature sensor.
8 .5 .1 A L f un cti o n
What measurement values are displayed depends on the selected program, the connected
8 .5 .2 A L Tse t
8 . 5 . 3 A L I n t e r v a l
sensors and the specific device design.
8 .5 .4 A L h e a t
1.1 OUTDOOR
9 .1 .1 Ou t d o o r
1.2 FLOW
9 . 1 . 2 F l o w
1.3 FLOW 2
9 . 1 . 3 D o m e s t i c h o t w a t er
9 .1 .4 Sen so r 4
1.4 SENSOR 4
9.1.5 Room
1.5 ROOM
9.1.6 Room sensor
1.6 ROOM SENSOR
9 .5 .1 Val v e t y p e
9.5.2 min angle
1.7 RC SWITCH
9.5.3 max angle
1.8 TARGET FLOW
9 .5 .4 Dir e ct io n
9 .5 .5 Tu r n time
1.9 TARGET FLOW 2
9.5.6 Pause f act or
If the cables are too long or the sensors are not placed optimally, the result may be
9 .5 .7 In cr ea se
9 .5 .8 Ca li br a tio n
small deviations in the measurement values. In this case the display values can be
9.6.1 Room sensor
compensated for by making entries on the controller. Follow the instructions under
9.6.2 Room r ef. day
menu 9.1
9.6.3 Room r ef. night
9.7.1 Aux. heat
9 .7 .2 E xtr a h ea ti n g cir c. 2
9 .7 .3 Wa i t p o si ti o n
9 . 7 . 4 H e a t d e l a y
9 . 7 . 5 Val v e d e l a y
Current temperature values with explanations.
Measurements" serves to display the currently
measured temperatures.
0ºC
The submenus described under 1.1-1.9 are available.
0ºC
The menu is closed by pressing "esc" or selecting
"Exit measurements".
Info
Selecting "Info" leads to a brief help text explaining
the measurement values.
Selecting "Overview" or "esc" exits the Info mode.
0ºC
Overview

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für ESBE 90C-2 series