Herunterladen Inhalt Inhalt Diese Seite drucken

Factory Default; Vttunnel - Videotec ULISSE MAXI NETCAM Bedienungsanleitung

Full ip ptz einheit fuer netzwerk-kameras fuer die dynamische ueberwachung grosser aussenbereiche
Vorschau ausblenden Andere Handbücher für ULISSE MAXI NETCAM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 195

10.1.16 Factory Default

If the password is no longer available, you
can also restore the factory settings by
pressing a Reset button situated inside the
base.
To restore the factory settings relative to the network,
user access and camera configuration follow this
procedure:
• Power the unit.
• Open the cover of the DIP-switches.
• Detect DIP switch 4 (01). Bring switch 1 down, 1
(ON) value.
• Wait for the temporary shutdownf of the LEDs (02).
• Bring switch 1 up, 0 (OFF) value.
• Close the connector housing cover.
Fig. 84

10.2 VTTunnel

The application works only with Java™. If
Java™ is not installed download the latest
version at www.java.com.
The application can be connected only to
the first interface of the network. Leave
only the network cable connected to the
pan & tilt.
The execution of the application requires
computer administrator privileges. The
following message may appear on the
screen: You have to execute Javaw as
administrator. In this case the execution
properties of the file in the Java installation
folder must be modified.
42
01
02
In order to connect the web camera you must use the
program VTTunnel, available in the Tools menu.
When the program starts, a list of networked devices
will be shown. To connect to the camera select the
pan & tilt desired and press the Connect key.
Once the connection is established, the web page of
the IP camera can be reached at 192.0.0.64.
When the operations on the camera are done, you
can close the connection by clicking the Disconnect
key. It is possible to connect to one camera at a time,
so you need to disconnect from the P&T unit before
operating on a different unit.
Fig. 85
Restart the Pan & Tilt if video streaming
parameters have been modified during the
configuration of the camera.