10.18
Alarm menu
The indicated data is only indicative
10.18.1
General alarm
GENERAL
BATTERY
ENTER
LINE BLACKOUT
LINE LACK
RS485 COMM. LACK
24V OVERLOAD
ENTER
LINE BLACKOUT
TOTAL:
STATUS:
COUNTER:
ENTER
LINE BLACKOUT
TOTAL:
STATUS:
-----
COUNTER:
STOP
-----
ENTER
LINE BLACKOUT
TOTAL:
STATUS:
------
COUNTER:
RESET
------
ENTER
98
ESC
ESC
0
----
RUN
----
ESC
0
ESC
0
ESC
LINE BLACKOUT: Shows the number of blackouts
detected in the mains voltage.
STATUS:
ON: (if no mains power)
OFF: (if there is mains power)
LINE LACK: Shows the voltage surges (gaps) detected.
STATUS:
ON: (voltage hole detected in the last 60 seconds)
OFF: (regular mains voltage)
RS485 COMM. LACK: Displays the number of
communication losses
STATUS:
ON: RS485 communication absent in at least one of the
two motors
OFF:
24V OVERLOAD: Number of overloads detected on
the external loads (photocells, etc.) 24 V power supply
output.
STATUS:
ON: current demand too high, safety device tripped
OFF: current drawn within limits
To see/modify the other functions, move onto the one
required (using the
same procedure.
STOP: interrupts the count
RESET: resets the count, keeping it at zero
To reset, press the ESC key, returning to the previous
menu.
Use the - key to go back in the sequence RESET > STOP
> RUN
RECOMMENDED SETTING: RUN (the count is functional)
Return to the previous menu
and
keys) and repeat the