Description of connections
5.1
Typical installation
3
3
8
9
It is the installer's responsibility to verify the adequacy of the cables in relation to the devices used in the
installation and their technical characteristics.
1
Power supply
2
Motor 1, Motor 2
3
Photocells - Receiver F4ES/F4S
4
Photocells - Transmitter F4ES/F4S
LED Flashing light R92/LED24 - FIFTHY/24
5
LED 24V
power supply
6
Antenna
Key selector R85/60
7
Key pad H85/TTD - H85/TDS
(connecting to H85/DEC - H85/DEC2)
H85/DEC - H85/DEC2
8
(connecting to control unit)
Gate open indicator
9
Power supply 24V
Courtesy light (Potential free contact)
10
Power supply 230V~ (100 W max)
(*) The two LNA, LNB connection cables are dedicated to serial communication and may have a reduced section
compared with the two +36V and 0V used to power the motor.
SUGGESTIONS: with existing installations, we recommend checking the cross section of the cables and that
the cables themselves are in good condition.
70
5
6
1
4
2
3W max
(max 10m); 1mm
2
4
Recommended cable
H07RN-F 2x1,5 mm
double insulated cable
2
Cable 4x1,5 mm² (max 10 m) - 4x2,5 mm² (max 20 m)
4x4 mm² (max 30 m) *
Cable 5x0,5 mm
(max 20 m)
2
Cable 3x0,5 mm
(max 20 m)
2
Cable 2x1 mm
(max 10 m)
2
Cable 50 Ohm RG58 (max 10 m)
Cable 3x0,5 mm
(max 20 m)
2
Cable 2x0,5 mm
(max 30 m)
2
Cable 4x0,5 mm
(max 20 m)
2
The number of conductors increases when using more
than one output contact on H85/DEC - H85/DEC2
Cable 2x0,5 mm
(max 10 m)
2
Cable 2x1 mm
(max 20 m)
2
(max 30m)
2