MOTOR 1 end of manoeuvre constant approach speed setting
Once deceleration is complete, the gate continues moving at a constant speed until it encounters the mechanical stop
(or the limit switch, if installed). The space is regulated by the parameters from Y and Y .
MOTOR 2 end of manoeuvre constant approach speed setting
Once deceleration is complete, the gate continues moving at a constant speed until it encounters the mechanical stop
(or the limit switch, if installed). The space is regulated by the parameters from Y and Y .
=minimum speed
...
=maximum speed
divided in constant size steps. The maximum setting for the approach speed is equivalent to 75% of the maximum
speed selectable using par.
Setting number of automatic closure attempts after activation of sensing edge or obstacle
detection (crush protection)
No automatic closure attempts.
From 1 to 3 automatic closure attempts. We recommend setting a value equal to or lower than the value set for
parameter
. Automatic closure is only performed if the gate is completely open.
Setting photocell mode during gate opening (FT1)
DISABLED. Photocell is not active or not installed.
STOP. The gate stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate opening.
TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed opening when the photocell
is cleared.
DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate closes when the photocell is cleared.
Setting photocell mode during gate closing (FT1)
DISABLED. Photocell is not active or not installed.
STOP. The gate stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate opening.
TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed opening when the photocell
is cleared.
DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate closes when the photocell is cleared.
Photocell (FT1) mode with gate closed
N.B.: this parameter is not visible if
If the photocell is obstructed, the gate cannot open.
The gate opens when an open command is received, even if the photocell is obstructed.
The photocell sends the gate open command when obstructed.
Setting photocell mode during gate opening (FT2)
DISABLED. Photocell is not active or not installed.
STOP. The gate stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate opening.
TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed opening when the photocell
is cleared.
DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate closes when the photocell is cleared.
Setting photocell mode during gate closing (FT2)
DISABLED. Photocell is not active or not installed.
STOP. The gate stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate opening.
TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed opening when the photocell
is cleared.
DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate closes when the photocell is cleared.
...
or
or
is set.