THERMAL MOT.1
THERMAL MOT.2
EXTRA TEMPERATURE
BATT. OPERATION
ENTER
DAYS
2
HOURS
2
MINUTES
15
SECONDS
2
ENTER
DAYS
2
HOURS
2
MINUTES
15
SECONDS
2
ENTER
DAYS
2
HOURS
2
MINUTES
15
RESET
SECONDS
2 ------
ENTER
96
ESC
ESC
RUN
----
ESC
STOP
-----
ESC
ESC
THERMAL MOT.1: Total time that MOTOR 1 thermal
protection has been active due to overheating.
THERMAL MOT.2: Total time that MOTOR 2 thermal
protection has been active due to overheating.
EXTRA TEMPERATURE: Time for which the temperature
has been outside the declared range (-20°C, +55°C).
BATTERY OPERATION: Total time the batteries have
been required to provide current (of present, only if
connected directly to terminals 3,4 with battery charger
B71/BCIPU).
To see/modify the other functions, move onto the one
required (using the
and
same procedure.
STOP: interrupts the count
RESET: resets the count, keeping it at zero
To reset, press the ESC key, returning to the previous
menu.