Alarms and faults
PROBLEM
ALARM
the safety devices page is
displayed without the STOP
panel blacked out (i.e. with the
STOP contact open)
the error alert SEL.MOT. is
displayed
the icon is displayed
the icon is displayed
The gate does not
open or close.
the icon is displayed
2
The photocells/
if the VL indicator (voltage
peripheral devices
supplied to 24 V output) on the
supplied via the 24 V
control menu page displays a
output switch off for
value of approximately 20 V
a few seconds, and
then switch on again.
14
Inverter module
The inverter module in the motor receives serial commands via RS485 from the control unit and controls the motor by
performing the required manoeuvre. In the event an obstacle is encountered, the manoeuvre is reversed automatically
and the alarm condition is transmitted to the control unit, which executes the same manoeuvre using the second motor,
if present, maintaining synchronisation of the automation system.
VISUAL INDICATIONS
RED LED (L1M)
•
operation
•
diagnostic icon on control unit display), see paragraph 10.5)
•
cable not connected correctly or RS485 drivers damaged
•
GREEN LED (L2M)
• Normally off
•
•
•
•
114
POSSIBLE CAUSE
the ST terminal is not connected
to the STOP button (N.C.) or is not
bridged with COM or F70/IPU36
has detected an alarm that must
prevent movement and forces a
STOP
the parameter
IPU36 does not correspond to the
value saved in the EEPROM of
inverter 1 or 2
the inverter was not initialised
when calibration the motor
the motor phases are not
connected to the respective
terminal block on the inverter
if the error alert appears on its
in inverter EEPROM, communications
1
suspended temporarily
connection error between F70/
IPU36 and inverter or damaged
inverter (or communication section
with inverter damaged on board
F70/IPU36)
it means there are too many
photocells/peripheral
connected (overload); a short
circuit has been detected on
the 24 V output (the electronic
protection device has tripped)
ACTION
install button or connect jumper.
Check the alarm reporting.
or
on F70/
save the correct value for the motor
in use
execute the motor calibration proce-
dure
check the motor phases are connected
to the inverter correctly, or if there
are any interruptions in the internal
connections
if this error alert appears on its own,
but no data storage operations are
currently in active, reroute the cables
to avoid the risk interference; check
the length and cross section of the
connecting cables
that the connection is correct; try
switching the F70/IPU36 off, and then
on again
reduce the load on the 24 V output,
devices
in accordance with the indications
table; check for any incorrect connections
or faulty devices that might overload
the output