Operation ILR11xx
6.2.12

Factory Preset

All settings are reset to delivery state. Go to the Factory Preset menu.
6.2.12
Password
Go to the Password menu to activate/deactivate the password protection. kann der Passwortschutz aktiviert/
Deaktiviert werden. With delivery the password protection is not active.
The password is permanently "1234" and cannot be changed. When the senosr is set to "Password ON" it is
only possible to quit operating mode when 1234 has been entered as password. Measuring mode continu-
es in the background whilst the password is being entered. Should no entry be made in the password input
menu over a period of approx. 10 seconds the operating mode reappears on the display.