4. INSTALLATION AND CONNECTION

4.1 Pump installation

The pumps may contain small quantities of residual water from testing. We advise flushing them briefly with clean water before their
final installation.
-
The electropump must be installed in a well ventilated place, protected from inclement
weather and with an environment temperature no higher than 40°C.
-
A solid anchoring of the pump to its support base helps absorb any vibrations created
by pump operation.
-
Always fit the pump on a base with the intake opening horizontal and the delivery
opening vertical.
-
The pump must be installed exclusively in horizontal position
- Do not allow the metal pipes to weigh down on the pump openings, transmitting excessive
strain, so as not to create deformations or breakages. Anchor the pipes separately if possible.
- The suction pipe must be as short as possible. For suction depths of more than 4 metres or
with long horizontal stretches, it is recommended to use a suction pipe with a diameter larger
than that of the suction opening of the electropump.
- To avoid the formation of air pockets in the suction pipe, ensure a slight positive tilt of the
same towards the electropump.
- To avoid transmitting vibrations to the system, after delivery it is recommended to use the
flexible pipe that is supplied inside the packing.
- If it is not possible to use the flexible pipe to make the connection, use only Teflon tape.
- For any maintenance jobs it is recommended:
to fit an interception valve along the pipe, close to the pump,
to use a straight length of pipe, after delivery, for lifting the cover of the Active system
in the event of inspection.
At suction from a well it is indispensable to install a foot valve complete with filter.
ENGLISH
Built-in non return valve and pressure gauge.
Possibility of remote alarm reset.
Protection against overpressure.
(the pump stops at over 10 bar)
Anticycling protection.
Helps prevent the formation of ice inside the pump. body
with forced cyclic running.
18