6.2
Downloading Welding Reports
The product is equipped with one USB interface for data transfer.
USB A Interface
for connecting a label tag printer and USB mass storage media
(such as a USB stick)
The interface complies with the USB version 1.1 specification (i.e.,
maximum data rate of 12 megabits per second).
When a data communication cable is connected, the print/download
sequence is initiated.
Before transferring data, it is highly recommended to switch
the welding unit off and on again. If this fails to happens,
there is a risk of data transfer failure, or reports in the weld-
Important
ing unit may be corrupted.
6.3

Selecting the File Format

Connecting the storage media causes the the screen to appear in which
the format of the output file with the welding reports can be selected:
a PDF file with an abstracted or extended version of the report or the
format of the welding data management application DataWork. Using
the ñ and ò arrow keys, select the file type you need and confirm
your selection by pressing the START/SET key.
The Service Report option is not important for normal operation. In
the scope of computer-assisted unit service, this report lists the events
related to the maintenance of the welding unit.
6.4

Downloading All Reports

After the file type was selected, the next screen offers a "Print All Re-
ports" option. Selecting it will download all welding reports currently
in system memory, or all of the previously selected welding process,
in the previously selected file format.
6.5
Downloading by Commission Number, Date or Report
Range
After the file type was selected, the next screen offers a "By Commis-
sion Number," a "By Date Range," and a "By Report Range" options.
Depending on the selection, the ñ and ò arrow keys can be used to
select from the commissions currently in system memory the desired
one, of which the reports should be downloaded, or the alphanumeric
keypad can be used (see first info in Sect. 4.1) to enter a start date
and an end date, or the first and the last report, that define a range
of dates or a range of reports of which the reports should be down-
loaded. When you press the START/SET key, you cause the selected
reports to be transferred to the storage media.
6.6

Understanding the Report Download Process

The download starts automatically after a selection was made among
the options. Wait for all the selected reports to transfer and the
"Download completed" message to appear on the screen.
If a problem occurs while the download is in progress, a "Not ready"
message shows. After the problem condition is cleared, the download
resumes automatically.
Version January 2020
HÜRNER HWT 400–WeldControl User's Manual
* Select File Type *
DataWork File
>PDF Abstract
PDF Ext'd Report
Display 33