Herunterladen Inhalt Inhalt Diese Seite drucken

Setting The Clock; Setting The Buzzer Volume; Understanding The "Recording" Sub-Menu; Entering Preformatted And User-Defined Traceability Data - Hürner HWT 400–WeldControl Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Use the arrow keys ñ and ò to select one of the options, "Deutsch,"
"English," and "Français" and confirmby pressing the START/SET key.

4.1.4 Setting the Clock

When the "Set Clock" sub-menu was selected, the screen changes and
the display reproduced in Display 7 appears.
The time of day and the date can be set using the keypad. The portions
"Hour," "Minute," "Day," "Month," and "Year" are set separately.
Press the START/SET key to confirm your settings.

4.1.5 Setting the Buzzer Volume

When the "Set Volume" sub-menu was selected, the screen changes
and the display reproduced in Display 8 appears. The buzzer can also
be heard. Turn the buzzer volume up or down to the desired value
using the ï, ð arrow keys (from 0 to 100) and confirm your setting
by pressing the START/SET key.

4.1.6 Understanding the "Recording" Sub-menu

"Welder Code on" means that the welder identification code has to
be entered as set with "Welder Code Options," "off," that this
is impossible.
"Commission Number on" means that the commission number (job
number) will have to be entered or confirmed before every new
welding, "off" that the user is not prompted to enter it.
"Joint Number on" means that the unit assigns an automatically in-
cremented joint number to every welding operation belonging
to a commission already known, and displays this number on the
screen next to the report number, "off" that no joint numbers
will be assigned at all.
"Additional Data on" means that the additional data will have to be
entered or confirmed before every new welding, "off" that the
user is not prompted to enter them.
"Fitting Code on" means that the second, so-called traceability code
of the fitting that is going to be worked has to be entered before
every welding, "off," that this is not possible.
"Pipe Codes on" means that the codes of both pipes/components (ISO-
compliant welding and treaceability codes) have to be entered
before every welding, "off," that this is not possible.
"Pipe Length on" means that the length of both pipes/components
has to be entered before every welding, "off," that this is not
possible.
"Weather Conditions on" means that the weather has to be selected
in a list before every welding, "off," that this is not possible.
"Installing Company on" means that the company that performs the
installation work has to be entered before every welding, "off,"
that this is not possible.
"Print Tags – M – " means that by pressing the MENU key, the user can
access a sub-menu for starting to print (a) label(s) with reference
to a given welding operation, with the optional label tag printer.
All data that are available encoded in a bar code can be read
using the handheld scanner.
Info
4.2 Entering Preformatted and User-defined Traceability Data
When the system is used in the WeldControl mode, all traceability data
enabled in the configuration menu at "Recording" (see Sect. 4.1.6)
have to be entered before the welding process. The welding unit
prompts the user to enter them before the welding process proper.
Version January 2020
HÜRNER HWT 400–WeldControl User's Manual
***** LANGUAGE *****
>Deutsch
English
Francais
Display 6
Date/Time
21.06.13
14:28
Display 7
Buzzer Volume
< ------20-------- >
Display 8
CONFIGURATION **
**
>Welder Code
On
Commission No.
On
Joint No.
Off
Display 9
EN