Command set

10.4.3 User single sensor tracking with timer (sNuh)

This command does the same as the command "User-configured tracking with buffering – Start
(sNuf)", but the unit sends the results directly to the output.
This command takes the "Set/Get user distance offset (sNuof)" and "Set/Get user
distance gain (sNuga)" into account.
Command
Return successful
Return Error
Parameters
 TR-Electronic GmbH 2011, All Rights Reserved
Page 150 of 156
Danger of physical injury and damage to property by undefined interface
states !
Never use these commands if more than one device is connected to
-
the RS-422 line.
Command
sNuh+xxx<trm>
gNuh+yyyyyyyy
<trm>
gN@Ezzz<trm>
Device ID (0..9)
N
Sampling time in 10 ms (if 0 -> use max. possible sample rate)
xxx
Distance in 0.1 mm
yyyyyyyy
Error code
zzz
TR - ELE - BA - DGB - 0021 - 06
Printed in the Federal Republic of Germany