Command set

10.4 Special user operation commands

The special user commands are user configurable and are an extension to the standard commands.
Use these commands carefully and only if you really understand their impact. The syntax of the user
commands differ to the standard commands as follows:
Standard commands:
User commands:
The user configuration parameters influence the result of the user commands. A gain and offset may
be applied to the measurement result and the output format may be configured.

10.4.1 User distance measurement (sNug)

Triggers simple distance measurement, similar to the command 10.2.1 "Distance measurement (sNg)"
on page 132. This command returns the distance corrected with the user offset and user gain as set
with the commands 10.5.2 "Set/Get user distance offset (sNuof)" on page 152 and 10.5.3 "Set/Get
user distance gain (sNuga)" on page 153. Each new command cancels an active measurement.
This command takes the "Set/Get user distance offset (sNuof)" and "Set/Get user
distance gain (sNuga)" into account.
Command
Return successful
Return Error
Parameters
 TR-Electronic GmbH 2011, All Rights Reserved
Page 148 of 156
sNxx
sNuxx
Command
sNug<trm>
gNug+xxxxxxxx
<trm>
gN@Ezzz<trm>
Device ID (0..9)
N
xxxxxxxx Distance in 0.1 mm
Error code
zzz
TR - ELE - BA - DGB - 0021 - 06