5.3.2.2 Manual start configuration

Configure the Digital Input (see 10.3.5.2 "Configure digital input (sNDI1)" om page 141) to activate the
external trigger to start measurements.
No.
Action
Activate digital
1
input DI1
Save settings
2
1)
Commands are described in chapter 10 "Command set" as of page 131
If the communication parameters of the device are lost, please reset the configuration to
the factory settings (9 "Factory settings" on page 130) using the reset button (see 8.2
"Reset switch" on page 125). Please note that the ID switch must be reset manually.

5.4 Measuring characteristics

The LLB-500(F) can be adapted to the requirements of different applications with measuring modes
for various reasons. The customization of measuring speed and measuring precision is made by
selection of the suitable measuring mode.
With the factory defaults the LLB-500(F) has at 2 σ a precision of ±1 mm for LLB500-00600 and
LLB500-00610 or ±3 mm for LLB500-00601 and LLB500-00611. The environmental conditions, such
as target surface, distance, environment illumination, influence the measuring speed. Good
environmental conditions (e.g. white targets or orange reflection panel at a dark environment) increase
the measuring speed.
For a description of the configuration command see 10.3.2 "Measuring characteristic configuration
(sNuc)" on page 137.
Printed in the Federal Republic of Germany
03/09/2016
Comment
Defines the action for a trigger event on
DI1.
Example for device 0:
Configure DI1 to start and stop
tracking. If DI1 is high, distances are
measured and the result is transferred
to the output at all interfaces. If DI1
goes to low, the measurement stops
The changed configuration must be
saved to make it permanent.
Example for device 0:
Save settings for device 0
TR - ELE - BA - DGB - 0021 - 06
Command
1)
s0DI1+3<trm>
1)
s0s<trm>
 TR-Electronic GmbH 2011, All Rights Reserved