Command set

10.2.5 Read out - Tracking with buffering (sNq)

After starting "tracking with buffering" with the command
from the device with the command
Command
Return successful
Return Error
Parameters

10.2.6 STOP/CLEAR command (sNc)

Stops the current execution and resets the status LEDs as well as the digital outputs.
Command
Return successful
Return Error
Parameters

10.2.7 Signal measurements (sNm)

Signal measurement can be done continuously or with a single measurement. The signal strength is
returned as a relative number in the typical range of 0 to 40 million.
The value for the signal strength is just approximately, it differs from device to device and also
depends on environment conditions.
Command
Return successful gNm+xxxxxxxx<trm>
Return Error
Parameters
 TR-Electronic GmbH 2011, All Rights Reserved
Page 134 of 156
sNq
.
Command
sNq<trm>
gNq+xxxxxxxx+c<trm>
<trm>
gN@Ezzz+c
Device ID (0..9)
N
Distance in 0.1 mm
xxxxxxxx
0 = no new measurement since last
c
1 = one new measurement since last
2 = more than one measurement since last
Error code
zzz
Command
sNc<trm>
gN?<trm>
<trm>
gN@Ezzz
Device ID (0..9)
N
Error code
zzz
Command
sNm+c<trm>
gN@Ezzz<trm>
Device ID (0..9)
N
0: single measurement
c
1: repetitive measurement
Signal strength (range 0.. 40 millions)
xxxxxxxx
Error code
zzz
TR - ELE - BA - DGB - 0021 - 06
, the last measurement can be read out
sNf
command
sNq
sNq
command, not overwritten
Use only with one sensor!
command, overwritten
sNq