10.3.6 Interface configuration (RS-422 / SSI)

The SSI interface is implemented in the LLB-500 and LLB-500F measuring systems only and
deactivated by default. Since the SSI interface uses the same connection as the RS-422 interface only
one of these two interfaces can be used at the same time.
Use the stand-alone mode with auto start to automatically update the SSI output
value. (See 10.3.3 "Set auto start configuration (sNA)" on page 138)
For further informations about the SSI-Interface see chapter 6.2.8 "SSI connection" on page 118 and
8.8 "SSI interface" on page 128.

10.3.6.1 Change between RS-422 and SSI output (sNSSI)

The configuration of the SSI interface must be carry out over the RS-232 interface
and the SSI master must not be connected while the configuration.
Connect the device by RS-232 to do the configuration and use the following commands:
Command
Return successful
Return Error
Parameters
Configuration parameters must be saved (see 10.3.8 "Save configuration parameters (sNs)" on page 145).
 TR-Electronic GmbH 2011, All Rights Reserved
Page 142 of 156
Set Command
sNSSI+c<trm>
gNSSI?
<trm>
gN@Ezzz<trm>
Device ID (0..9)
N
binary coded:
xxx
Bit0 = 0: RS-422 interface is active (SSI is deactivated)
1: SSI interface is active (RS-422 is deactivated)
Bit1 = 0: Binary coded data output
1: Gray coded data output
Bit2 = 0: no error bit output
1: error bit attached to the output data value
Bit3 = 0: no additional error code output
1: attach 8 bit error code (Code -200)
Bit4 = 0: 24 bit data value
1: 23 bit data value
Error code
zzz
TR - ELE - BA - DGB - 0021 - 06
Get Command
sNSSI<trm>
gNSSI+c<trm>
gN@Ezzz<trm>
Printed in the Federal Republic of Germany