5.3.1.1 Configuration

After connecting the device, the steps below are necessary to configure the LLB for the controlled
interface mode.
No.
Action
1
Set ID switch
2
Set controlled mode
Set communication
3
parameters
1)
Commands are described in chapter 10 "Command set" as of page 131
If the communication parameters of the device are lost, please reset the configuration to
the factory settings (9 "Factory settings" on page 130) using the reset button (see 8.2
"Reset switch" on page 125). Please note that the ID switch must be reset manually.

5.3.1.2 Host software

Host software is required for operation of the LLB in controlled mode. When connecting multiple
devices to a single serial RS-422 line, strict Master-Slave communication must be implemented
(LLB operates as slave).
Printed in the Federal Republic of Germany
03/09/2016
Comment
Changes of the device ID are
activated after a power cycle.
Example for device 0:
Change the ID Switch to position 0
Set the LLB to the controlled mode, if
not already in controlled mode.
Example for device 0:
Set to controlled mode by means of
the stop command.
If necessary, change the settings for
the serial interface.
Example for device 0:
Set serial interface to 19200 Baud,
8 Bit, no Parity
Danger of physical injury and damage to property by accidentally
commands !
Careful testing of the host software together with the devices prior to
-
installation is strongly recommended.
TR - ELE - BA - DGB - 0021 - 06
Command
Set ID switch to position 0
Power OFF; Wait 10 s;
Power ON
1)
sac<trm>
1)
s0br+2<trm>
Power OFF; Wait 10 s;
Change settings on the host;
Power ON
 TR-Electronic GmbH 2011, All Rights Reserved