Herunterladen Inhalt Inhalt Diese Seite drucken

User-Configured Tracking With Buffering - Start (Snuf); Read Out - User-Configured Tracking With Buffering (Snuq) - TR-Electronic _LLB500(F)-00601 Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10.4.4 User-configured tracking with buffering – Start (sNuf)
The continuous distance measuring (tracking) starts. The measurements are internally saved in the
device (memory for one measurement). The measured distance is corrected with the user offset and
user gain as set with the commands "Set/Get user distance offset (sNuof)" on page 152 and 10.5.3
"Set/Get user distance gain (sNuga)" on page 153. Define the rate of measurements with the
sampling time. If the sampling time is set to zero, the measurements are executed as fast as possible
(Speed dependent on target conditions). The last measurement can be read out from the device with
the command "Read out – User-configured tracking with buffering (sNuq)". The measurements are
continued until the "STOP/CLEAR command (sNc)" is issued.
This command takes the "Set/Get user distance offset (sNuof)" and "Set/Get user
distance gain (sNuga)" into account.
Command
Return successful
Return Error
Parameters
10.4.5 Read out – User-configured tracking with buffering (sNuq)
After starting the command "User-configured tracking with buffering – Start (
measurement can be read out from the LLB with the command "Read out – User-configured tracking
with buffering (
sNuq
)".
This command takes the "Set/Get user distance offset (sNuof)" and "Set/Get user
distance gain (sNuga)" into account.
Command
Return successful
Return Error
Parameters
Printed in the Federal Republic of Germany
03/09/2016
Set Command
sNuf+xxxxxxxx<trm>
gNuf
<trm>
gN@Ezzz<trm>
Device ID (0..9)
N
Sampling time in 10 ms (if 0 -> use max. possible sample rate)
xxxxxxxx
Error code
zzz
Command
sNuq<trm>
gNuq+xxxxxxxx+c<trm>
<trm>
gN@Ezzz+c
Device ID (0..9)
N
Distance in 0.1 mm
xxxxxxxx
0 = no new measurement since last
c
1 = one new measurement since last
2 = more than one measurement since last
overwritten
Error code
zzz
TR - ELE - BA - DGB - 0021 - 06
Get Command
sNuf
<trm>
gNuf+xxxxxxxx
<trm>
gN@Ezzz<trm>
sNuf
command
sNuq
command, not overwritten
sNuq
sNuq
 TR-Electronic GmbH 2011, All Rights Reserved
)", the last