10.5 Special User configuration commands

10.5.1 Set user auto start configuration (sNuA)

This command activates the user stand-alone mode with auto start of the LLB measuring system. It
triggers continuous measurement of the distance. The distance output at the serial interface (RS-232
and RS-422) is corrected with the user offset and user gain as set with the commands "Set/Get user
distance offset (sNuof)" on page 152 and "Set/Get user distance gain (sNuga)" on page 153. The
analog, digital and SSI outputs are updated according to the measured distance values. The sampling
time defines the measurement rate. If the sampling time is set to zero, the measurements are
executed as fast as possible (depending on target conditions).
In difference to the command "Set auto start configuration (sNA)", this command returns measuring
results according to the user parameters.
The user stand-alone mode with auto start is active until the command "STOP/CLEAR command
(sNc)" is received by the device.
The operating mode is stored in the LLB and activated immediately. This mode is
also activated after next power ON.
Internally command
read out from the device with the command
Command
Return successful
Return Error
Parameters

10.5.2 Set/Get user distance offset (sNuof)

The user can set an individual overall offset correction for all distance measurement commands in this
Special User Command' section. The standard distances measurement commands are not involved
(see chapter 5.5.1 "Offset / Gain" on page 111).
Command
Return successful gNuof?<trm>
Return Error
Parameters
Configuration parameters must be saved (see 10.3.8 "Save configuration parameters (sNs)" on page 145).
 TR-Electronic GmbH 2011, All Rights Reserved
Page 152 of 156
is started. Therefore the last measurement can also be
sNuf
Command
sNuA+xxxxxxxx <trm>
gNuA?<trm>
<trm>
gN@Ezzz
Device ID (0..9)
N
xxxxxxxx Sampling time in 10 ms (if 0 -> use max. possible sample rate)
Error code
zzz
Set Command
sNuof+xxxxxxxx<trm>
<trm>
gN@Ezzz
Device ID (0..9)
N
Offset in 1/10 mm; + positive / - negative
xxxxxxxx
Error code
zzz
TR - ELE - BA - DGB - 0021 - 06
sNuq
.
Get Command
sNuof<trm>
gNuof+xxxxxxxx<trm>
<trm>
gN@Ezzz
Printed in the Federal Republic of Germany
03/09/2016