Command set

10.6 Error codes

No.
Format
203
@E203
210
@E210
211
@E211
212
@E212
220
@E220
@E230
230
231
@E231
232
@E232
233
@E233
234
@E234
236
@E236
252
@E252
253
@E253
254
@E254
255
@E255
256
@E256
@E257
257
258
@E258
@E259
259
260
@E260
@E263
263
264
@E264
330
@E330
331
@E331
360
@E360
361
@E361
not listed
Before contacting TR-Electronic, please collect as much information as possible.
 TR-Electronic GmbH 2011, All Rights Reserved
Page 154 of 156
Meaning
Wrong syntax in command, prohibited parameter in command entry or non-
valid result
Not in tracking mode, start tracking mode first.
Sampling too fast, set the sampling time to a larger value.
Command cannot be executed, because tracking mode is active, first use
command sNc to stop tracking mode.
Communication error
Distance value overflow caused by wrong user configuration.
Change user offset (and/or user gain)
Wrong mode for digital input status read.
Digital output 1 cannot be set if configured as digital input
Number cannot be displayed, check output format.
Distance out of range
Digital output manual mode (DOM)
cannot be activated when configured as digital input
Temperature too high
(contact TR-Electronic if error occurs at room temperature)
Temperature too low
(contact TR-Electronic if error occurs at room temperature)
Bad signal from target
It takes too long to measure according distance
Received signal too weak, distance
(Use different target and distances, if the problem persists,
please contact TR-Electronic)
Received signal too strong
(Use different targets and distances, if the problem persists,
please contact TR-Electronic)
Too much background light
(Use different target and distances, if the problem persists,
please contact TR-Electronic)
Power supply is too high
Power supply voltage is too low
Distance cannot be calculated because ambiguous targets. Use clear
defined targets to measure the distance.
Too much light, use only reflective target plates from TR-Electronic.
In moving target characteristic, distance jump occurs
Too much light, measuring on reflective targets not possible
Acceleration of the target too strong or distance jump
(in moving target characteristic only)
Over speed of target (in moving target characteristic only)
Measuring time is too short
Measuring time is too long
Hardware failure (Contact TR-Electronic)